| Technology |
| Standard |
EIA/TIA-232 RS-232 (ITU-T v.28)
EIA/TIA-422 RS-422 (ITU-T v.11)
EIA/TIA-485 RS-485 (ISO/IEC8284) |
| Interface |
|
| Auto baud rate 300 to 921.6Kbps |
|
|
|
|
RS-232 x1
RS-422 x1
RS-485 2/4 wire x1 | |
|
|
|
RS-232: DB-9 Female
RS-422/485: Removable terminal block
| |
|
|
|
RS-232: 50 feet
RS-422: 4000 feet
RS-485: 4000 feet | |
|
|
|
RS-422: TxD+, TxD-, RxD+, RxD-
RS-485 4 wires: TxD+, TxD-, RxD+, RxD-
RS-485 2 wires: Data+, Data-
Signal Ground | |
|
|
DIP-switch 1,2: RS-422/485 wiring mode selection.
DIP-switch 3,4: RS-422/485 line terminator selection.
DIP-switch 5,6: RS-422/485 biasing resistor selection. |
| |
|
|
System power (Pwr): Green
Receive Data (Rx):Yellow blinking
Transmit Data (Tx): Green blinking
| |
| Power Requirements |
|
|
| DC 12~48V input with polarity reverse correction. | |
|
|
|
| Mechanical |
|
Wall mount or DIN Rail mount |
|
|
|
|
24.7mm(H) x 74mm (W) x99 mm (D) |
|
|
|
|
0.24kg with package
0.15kg without package | |
| Environmental |
|
|
|
|
|
|
0% to 90% (Non-condensing) | |
|
-40 to 80°C (-40 to 176°F) |
|
|
|
|
| Regulatory Approvals |
|
FCC class B, CE/EN55022 class B
CE/EN61000-3-2:2001 Harmonic test
CE/EN61000-3-3: 1995 Flicker test |
|
|
|
|
|
|
|
|
5366,967 Hours ,MIL-HDBK-217F |
|
|
|