| Technology |
|
|
|
IEEE802.3 10Base-T IEEE802.3u 100Base-TX IEEE802.3ab 1000Base-T IEEE802.3z Gigabit Ethernet Fiber IEEE802.3x flow control and back pressure IEEE802.1p Class of Service
| |
| Performance |
|
|
|
Store and Forward Technology with 32Gbps Switch Fabric. | |
|
|
|
14,880pps for 10M Ethernet, 148,800pps for 100M Fast Ethernet, 1,488,100 for Gigabit Ethernet | |
|
|
|
64 bytes to 1522 bytes (with VLAN Tag) | |
|
|
|
|
|
|
1Mbits shared packet buffer | |
|
|
|
Compliance with IEEE802.1p class of service with Tag Based Priority rule Per switch port provides 4 priority queues with 8 (Higher):4(High):2(Low):1(Lower) scheduling. The Tag Priority ID as following: Higher (6,7), High (4,5), Low (0,3), Lowest (1,2) | |
| Interface |
|
|
|
7 x 10/100 Base-TX with Auto MDI/MDI-X function Auto-Negotiation 3 x 1000Base-T supports Auto MDI/MDI-X , Auto-Negotiation function and combo with Small Form Factor Package (SFP) socket
| |
|
|
|
10/100 Base-TX: RJ-45 1000Base-T: RJ-45 SFP: supports all 3.3v SFP type Gigabit fiber transceiver Power: 4-Pin Removable Terminal Block connector
| |
|
|
|
RJ-45 connector: supports CAT-3, CAT-4, CAT-5 unshielded twisted pair or shielded twisted pair cable. The link distance is maximum 100 meters
| |
|
|
|
System Power: Power 1 (Green), Power 2 (Green) 10/100 Mbps RJ-45 port: Link/Activity (Green), Full Duplex/ Collision (Yellow) port: Link/Activity(Green) 1000Base-T RJ-45 port: Link/Activity (Green) SFP port: Link/Activity (Green) | |
| Power Requirements |
|
|
|
4 pins terminal block for power input. DC 24V (12~48V) with polarity reverse protection and redundant function | |
|
|
|
11.5 Watts @ DC 24V(Maximum) | |
| Mechanical |
|
|
|
DIN-Rail mount or Wall Mount | |
|
|
|
Aluminum metal case with IP31 grade case protection for drop-waterproof and dustproof | |
|
|
|
137.85mm(H) x 96mm (W) x 132mm (D)( with DIN rail clip) | |
|
|
|
| Environmental |
|
|
|
|
|
|
0% to 95% (Non-condensing) | |
|
|
|
|
|
|
0%~ 95%, (non-condensing) | |
|
|
|
1.2KV on port to port and port to power | |
| Regulatory Approvals |
|
|
|
EN55022 CLASS A, EN61000-3-2,
EN61000-3-3, EN61000-6-4
| |
|
|
|
EN55024, EN61000-6-2, IEC 61000-4-2,
IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11,
IEC 61000-6-2 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|